Loop Mux Registers Reference
199
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Loop Mux
5.14.6 Filter Mux Register (FILTERMUX)
Address 00020014
Figure 5-7. Filter Mux Register (FILTERMUX)
29
28
27
26
25
24
FILTER2_KCOMP_SEL
FILTER1_KCOMP_SEL
FILTER0_KCOMP_SEL
R/W-00
R/W-00
R/W-00
23
19
18
17
16
Reserved
FILTER2_
FFWD_SEL
FILTER1_
FFWD_SEL
FILTER0_
FFWD_SEL
R-0 0000
R/W-0
R/W-0
R/W-0
15
14
13
12
11
10
9
8
Reserved
FILTER2_PER_SEL
FILTER1_PER_SEL
FILTER0_PER_SEL
R-00
R/W-00
R/W-00
R/W-00
7
6
5
4
3
2
1
0
Reserved
FILTER2_FE_SEL
FILTER1_FE_SEL
FILTER0_FE_SEL
R-00
R/W-10
R/W-01
R/W-00
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 5-7. Filter Mux Register (FILTERMUX) Register Field Descriptions
Bit
Field
Type
Reset
Description
29-28
FILTER2_KCOMP
_SEL
R/W
00
Selects KComp value routed to Filter 2 Module
0 = KComp 0 Value Selected (Default)
1 = KComp 1 Value Selected
2 = KComp 2 Value Selected
27-26
FILTER1_KCOMP
_SEL
R/W
00
Selects KComp value routed to Filter 1 Module
0 = KComp 0 Value Selected (Default)
1 = KComp 1 Value Selected
2 = KComp 2 Value Selected
25-24
FILTER0_KCOMP
_SEL
R/W
00
Selects KComp value routed to Filter 0 Module
0 = KComp 0 Value Selected (Default)
1 = KComp 1 Value Selected
2 = KComp 2 Value Selected
23-19
Reserved
R
0 0000
18
FILTER2_FFWD
_SEL
R/W
0
Configures Feedforward value routed to Filter 2 Module
0 = Filter 0 Output Selected (Default)
1 = Filter 1 Output Selected
17
FILTER1_FFWD
_SEL
R/W
0
Configures Feedforward value routed to Filter 1 Module
0 = Filter 0 Output Selected (Default)
1 = Filter 2 Output Selected
16
FILTER0_FFWD
_SEL
R/W
0
Configures Feedforward value routed to Filter 0 Module
0 = Filter 1 Output Selected (Default)
1 = Filter 2 Output Selected
15-14
Reserved
R
00
13-12
FILTER2_PER
_SEL
R/W
00
Selects source of switching cycle period for Filter 2 Module
0 = DPWM 0 Switching Period (Default)
1 = DPWM 1 Switching Period
2 = DPWM 2 Switching Period
3 = DPWM 3 Switching Period