Loop Mux Registers Reference
192
SNIU028A – February 2016 – Revised April 2016
Copyright © 2016, Texas Instruments Incorporated
Loop Mux
Table 5-2. Front End Control 0 Mux Register (FECTRL0MUX) Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
9
DPWM1_FRAME_
SYNC_EN
R/W
0
Enables DPWM Trigger from DPWM 1 Frame Sync to Front End Control
0 = DPWM 1 Frame Sync not routed to Front End Control (Default)
1 = DPWM 1 Frame Sync routed to Front End Control
8
DPWM0_FRAME_
SYNC_EN
R/W
0
Enables DPWM Trigger from DPWM 0 Frame Sync to Front End Control
0 = DPWM 0 Frame Sync not routed to Front End Control (Default)
1 = DPWM 0 Frame Sync routed to Front End Control
7
DPWM3_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-B to Front End Contro
l0 = DPWM 3 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-B trigger routed to Front End Control
6
DPWM2_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-B trigger routed to Front End Control
5
DPWM1_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 1 PWM-B to Front End Control
0 = DPWM 1 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 1 PWM-B trigger routed to Front End Control
4
DPWM0_B_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 0 PWM-B to Front End Control
0 = DPWM 0 PWM-B trigger not routed to Front End Control (Default)
1 = DPWM 0 PWM-B trigger routed to Front End Control
3
DPWM3_A_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 3 PWM-A to Front End Control
0 = DPWM 3 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 3 PWM-A trigger routed to Front End Control
2
DPWM2_A_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 2 PWM-B to Front End Control
0 = DPWM 2 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 2 PWM-A trigger routed to Front End Control
1
DPWM1_A_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 1 PWM-B to Front End Control
0 = DPWM 1 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 1 PWM-A trigger routed to Front End Control
0
DPWM0_A_TRIG_
EN
R/W
0
Enables DPWM Trigger from DPWM 0 PWM-B to Front End Control
0 = DPWM 0 PWM-A trigger not routed to Front End Control (Default)
1 = DPWM 0 PWM-A trigger routed to Front End Control