TELELIFT 3713 SX
TECHNICAL SPECIFICATIONS
60
Document 57.4402.9200 - 1
st
Edition 10/2006
INDEX
LIST OF THE DLE PARAMETERS
N°
Winscope Name
Description
00
C1cellaVuoto
Value saved in analog channel 1 - calibration with unloaded machine
(best setting around 700).
01
C1cellaCarico
Value saved in analog channel 1 - calibration with loaded machine
(best setting around 300).
02
C1cellaMin
Min admissible value for analog channel 1 reading (if actual value is
below: alarm 2) (value set at 10 roughly).
03
C1cellaMax
Max admissible value for analog channel 1 reading (if actual value is
above: alarm 2) (value set at 1010).
04
C2cellaVuoto
Value save in analog channel 2 - calibration with unloaded machine
(best setting around 300).
05
C2cellaCarico
Value save in analog channel 2 - calibration with loaded machine (best
setting around 700).
06
C2cellaMin
Min admissible value for analog channel 1 reading (if actual value is
below: alarm 3) (value set at 10 roughly).
07
C2cellaMax
Max admissible value for analog channel 1 reading (if actual value is
above: alarm 3) (value set at 1010).
08
Filter
Number of filter samples, with mobile mean. Load cell reading. Max
5.
09
paCellaUnica
Sets to 1 automatically (during the machine selection) when the DLE
is used in single channel mode.
10
Celle_MaxDelta
Max admissible delta between readings of analog channels 1 and 2,
expressed as a %, default 10 (current 20).
11
SpanForche
Limiter intervention percentage in case of work with stabilised machine
and forks. Default: 100 (as per calibration).
12
SpanNavicella
Limiter intervention percentage in case of work with stabilised machine
and platform (changed by the relevant procedure during calibration).
When the platform is selected, the limiter uses this % (default 110%
- load increase of 10%) instead of the SpanForche datum (current
value 125).
13
DeltaSpanGomme
Limiter intervention percentage in case of work with non-stabilised
machine (changed by the relevant procedure during calibration).
% value that adds to the calibration with forks and outriggers
(SpanForche).
14
OffSet0
Command given to the digital potentiometer for cell 1 (value from 0 to
255) to set the reading scale during calibration with unloaded machine
to a certain pre-set value (about 900 bit ADC - C1cellaVuoto) (about
700).
15
OffSet1
Command given to the digital potentiometer for cell 2 (value from 0 to
255) to set the reading scale during calibration with unloaded machine
to a certain pre-set value (about 200 bit ADC - C2cellaVuoto) (about
300).
16
paIsteresiSblocco
Load % for the reset of the movements once the block condition has
been rectified. (default 5% = 95%).
17
paRitardoSblocco
Value expressed in tenths of second corresponding to the time that
must elapse between the block condition and the movement reset
(default 10 = 1 second).