CALIBRATING THE DLE LOAD LIMITER
• During the calibration mode the limiter device
doesn’t block any manoeuvres so the calibration
can be done.
• If the machine is equipped with stabilisers, you
shall lower the stabilisers to the ground and
calibrate the system with the machine "empty"
and "loaded" . Therefore, we recommend keeping
the load of known weight in the range of action of
the machine.
• The calibration of the machine should be done
after a few minutes of use, in other words with
the machine “warm”.
- Enter the calibration mode:
Within 5 seconds from when the instrument is activated
(even if the display is still off) you should press the
keys on the front panel in the right sequence.
The keys to use and the relevant meaning are shown
below:
Press
to enter number 0
Press
to enter number 1
Press
to confirm the sequence entered.
The access code currently used is
1001
. Therefore
you should enter the following sequence:
1
0
0
1
CONFIRM
If the sequence is correct the confirmation of the
instrument functioning in the calibration mode is
given by the LED near
lighting with a fixed
light.
The display shows a number that ISN’T blinking,
starting from “0”.
1
4
5
6
7
8
10
9
- Description of the controls:
1
Calibration selection button
Display
Stability indicator with LED-bar
4
Green light - power OK
5
Yellow light - calibration mode
6
Calibration confirmation button
7
Not used
8
Red light - outrigger position
9
Buzzer ON/OFF pushbutton
10
Red light - overload pre-alarm / alarm
The digit on display
shows the selected attachment.
The user can choose among:
0: Generic
The system recognises the attachment fitted to the
machine automatically.
55.0016.0022