TELELIFT 3713 SX
TECHNICAL SPECIFICATIONS
4
Document 57.4402.9200 - 1
st
Edition 10/2006
INDEX
Connections:
1
- load cell output
+ load cell output
- load cell excitation
4
+ load cell excitation
5
- power supply (connected to ground)
6
+ power supply (protected by a fuse)
7
stabiliser input (positive signal when both stabilisers are down)
8
alarm output (200 mA max.) A positive voltage is present when the alarm is not activated
S
load cell shield (not connected to the instrument). The shield of the cable is connected to the body of the load
cell: once the cell is fitted on the rear axle, the shield is connected to ground (chassis).
The
ADOS
or
NBC
load cells are interchageable. Refer to the following table for the wire coulour identification
Pos.
ADOS cell
NBC cell
1
2
3
4
White (cell output)
Green (cell output)
Red (+ 5V cell power supply)
Black (ground)
Yellow
Green
Red and white (join the wires)
Black and blue (join the wires)