TELELIFT 3713 SX
TROUBLESHOOTING
5
8
Document 57.4402.9200 - 1
st
Edition 10/2006
INDEX
Problem
Cause
Solution
The heating fan doesn’t work
The sensor checking the low boom
position doesn’t work
The air filter restriction indicator light
doesn’t work
The engine cooling oil temperature
indicator light doesn’t work
The Perkins engine oil pressure light
indicator doesn’t work
Electric connecting lines.
15A fuse
F
interrupted.
Fan control switch
S0
damaged.
Heating fan motor M5 damaged.
Electric connecting lines.
10A fuse
F18
interrupted.
Sensor
B8
damaged.
Electric connecting lines.
Dashboard indicator light
X1
defective.
Filter restriction sensor
B15
damaged.
Electric connecting lines.
Te m p e r a t u r e s e n s i n g b u l b
B 1
damaged.
Dashboard indicator light
X1
defective.
Electric connecting lines.
Pressure switch
B11
for low engine oil
pressure damaged.
Dashboard indicator light
X1
defective.
Check the line continuity and repair if
necessary.
C h e c k t h e f u s e a n d r e p l a c e i f
necessary.
Check the switch and replace if
necessary.
Check the fan motor and replace if
necessary.
Check the line continuity and repair if
necessary.
C h e c k t h e f u s e a n d r e p l a c e i f
necessary.
Check the sensor and replace if
necessary.
Check the line continuity and repair if
necessary.
Check the indicator light and replace if
necessary.
Check the sensor and replace if
necessary.
Check the line continuity and repair if
necessary.
C h e c k t h e b u l b a n d r e p l a c e i f
necessary.
Check the indicator light and replace if
necessary.
Check the line continuity and repair if
necessary.
Check the pressure switch on the
engine and replace if necessary.
Check the indicator light and replace if
necessary.