INDEX
DISPLAY
FUNCTION
0
The LED bar indicates the type of machine in use:
1 LED on - Telelift 4013 sx
To select the machine to be calibrated press
to increase the number of LED's lit or
press
to reduce the number of LED's lit.
If you are doing the first calibration, press
to reset the system and load the default
parameters of the selected machine.
If you are re-calibrating the instrument, directly jump to point 1.
Press
to proceed to the next point (1).
1
Lower the stabilisers to the ground, fully retract the boom holding it slightly above the
horizontal with respect to the ground.
DON’T
lift loads.
Press
to confirm the
EMPTY
calibration of the machine. The audible alarm will sound
to confirm the command has been executed.
Press
to proceed to the next point (2).
Again with the stabilisers lowered to the ground, place a load on the forks with a weight of
1000 kg, extend the boom while holding it horizontal till reaching the overturning moment
corresponding to 7.30 metres (overturning distance = distance from the front part of the
wheels to the centre of the load).
Press
to confirm the
LOADED
calibration of the machine and check that the alarm
triggers. The audible alarm will sound to confirm the command has been executed.
Move the boom fully in while holding the same in the horizontal position.
Press
to proceed to the next point (3).
With the outriggers raised and the boom horizontal, place a load on the forks with a weight
of 1000 kg, and extend the boom up to a distance of 5.10 metres (measured from the
front part of the wheels to the centre of the load placed on the forks).
Press
some times to switch off the LED's showing the load percentage and press
to switch them on. By the end of the operation, all LED's from the left to the right
must be lit, but for the last red LED. To do this, we recommend starting with the LED's
bar on the green area and then press to increase the number of LED's lit.
No confirmation is required as the operation is automatically saved at the end of the
adjustment.
Press
several times to proceed to the next point (F).
F
Press
to exit calibration and to
SAVE
the changes made (the audible alarm sounds
and the LED’s come on to confirm that data have been saved).
The limiter is no longer in the calibration mode. The LED
is not lit fixed any more.
You should turn the machine off and then on again to eliminate any alarm messages.
Now you can start working.