TELELIFT 3713 SX
TROUBLESHOOTING
5
7
Document 57.4402.9200 - 1
st
Edition 10/2006
INDEX
Problem
Cause
Solution
10A fuse
F18
interrupted.
Outrigger micro-switches damaged.
Electric line connecting the micro-switches
to the DLE.
Socket
X5
on DLE defective.
DLE display damaged.
10A fuse
F5
interrupted.
Road/Jobsite selector
S
damaged.
Steer mode selector
S
damaged.
Spools
Y0
-
Y1
of the crab or four-wheel
steering selection solenoid damaged.
Electric connecting lines.
10A fuses
F10
or 15A
F1
interrupted.
Relay
K5
interrupted.
Horn button
SX11
on speed selector
damaged.
Horn
H0
damaged.
Electric connecting lines.
7.5A fuse
F11
interrupted.
Beacon
X101
damaged.
The B6 system doesn’t change
scale when the machine is on wheels
or stabilised
No steering mode selction (two-
wheels, four-wheels, crab)
The horn doesn’t work
The beacon doesn’t work
C h e c k t h e f u s e a n d r e p l a c e i f
necessary.
Check the micro-switches and replace
if necessary.
Check the line continuity and repair if
necessary.
Check the pins of the signal inputs; if
damaged, replace the socket.
Change the DLE.
C h e c k t h e f u s e a n d r e p l a c e i f
necessary.
Check the selector and replace if
necessary.
Check the selector and replace if
necessary.
Check the spools and replace if
necessary.
Check the line continuity and repair if
necessary.
Check the fuses and replace if
necessary.
Check the relay and replace if
necessary.
Check the button and replace if
necessary.
Check the horn and replace if
necessary.
Check the line continuity and repair if
necessary.
C h e c k t h e f u s e a n d r e p l a c e i f
necessary.
Check the beacon and replace if
necessary.