TELELIFT 3713 SX
TECHNICAL SPECIFICATIONS
45
Document 57.4402.9200 - 1
st
Edition 10/2006
INDEX
CONNECTOR X1 FOR CHECKS WITH TESTER
Electrical power to control unit (DLE)
Pin 1: 12 V
Pin 2: ground
Overload signal (1V generated by the DLE)
Pin 18: 12 V normal conditions, 0 V alarm overload
Pin 7: re-reading overload signal
Electrical power to load cell equal to 5 V
Channel 1: Pin 16: positive
Pin 17: negative
Load cell signal in range 0,1 - ,5 mV
Channel 1: Pin 10: positive
Pin 9: negative
Machine without load on the forks, non stabilised,
with boom horizontal and not extended
Pin 9 and 10:
1,1 - 1,2 - 1,3 - 1,4 mV
Machine without load on the forks, non stabilised,
with boom horizontal and fully extended
Pin 9 and 10:
0,1 - 0,2 - 0,3 - 0,4 mV
Lowered stabilisers signal
Pin 20: 12 V
Pin 21: 12 V
Pin 1
Pin 8
Pin 16