TELELIFT 3713 SX
TECHNICAL SPECIFICATIONS
40
Document 57.4402.9200 - 1
st
Edition 10/2006
INDEX
Final Inspection
A final inspection must be carried out after any intervention
on or calibration of the overload warning system:
•
Ensure the system is functioning properly and is
correctly calibrated.
•
Make sure the main module case and the display are
firmly in place inside the cab and are not touching
hydraulic hoses or any moving part.
• Make sure all cables are firmly held in place, in order
to prevent them from rubbing or vibrating.
•
Check the main module and its connector for
cleaness. To remove oil residues, use a clean towel
and ethyl alcohol; blow off any dust with compressed
air.
•
Fill out the calibration seal with date and
signature.
•
Apply the calibration seal on the main module, over
the trimmer access holes.