ULTRAFLOW 150 GAS FLOW AND TEMPERATURE MONITOR
Table 6-4A
Multi I/O Jumper Definitions
Jumper #
Selections
Functional Description
4--20
ma
0--20
ma
0—24
ma
JU1
1
0
1
Jumpers JU
1
& JU
2
configure the range of the
analog outputs for channel #1.
JU2
0
1
1
JU3
1
0
1
Configures the range of analog output #2
JU4
0
1
1
JU5
1
0
1
Configures the range of analog output #3
JU6
0
1
1
JU7
1
0
1
Configures the range of analog output #4
JU8
0
1
1
Dry Contact
5
vdc
Digital
JU9
1—2—3
1—2—3
Configures digital input #1 hardware to work with
dry contact or 5
vdc
logic signals
JU10
1—2—3
1—2—3
Configures digital input #2 hardware.
JU11
1—2—3
1—2—3
Configures digital input #3 hardware.
JU12
1—2—3
1—2—3
Configures digital input #4 hardware.
JU13
1—2—3
1—2—3
Configures digital input #5 hardware.
JU14
1—2—3
1—2—3
Configures digital input #6 hardware.
JU15
1—2—3
1—2—3
Configures digital input #7 hardware.
JU16
1—2—3
1—2—3
Configures digital input #8 hardware.
Ram
128K
Ram
32K
ROM
128K
ROM
64K
ROM
32K
Flash
128K
Flash
64K
Flash
32K
JU17
A
A
B
B
B
B
B
B Jumpers JU
17
& JU
18
together, select the type of
memory chips to be used.
JU18
D
D
C
C
B
C
C
A
JU19
IN-----OUT
Double terminated
IN-----OUT
Single terminated
Selects whether the network termination will be
single or double termination. This is usually done
elsewhere
JU20
IN-----OUT
Out = unterminated
IN-----OUT
IN = terminated
Terminates the network if necessary. This is usually
done elsewhere.
JU21
1
2 3
2 3
K1 Contact: 2 3 = NO 1 2 = NC
JU22
1
2 3
2 3
K2 Contact: 2 3 = NO 1 2 = NC
JU23
1
2 3
2 3
K3 Contact: 2 3 = NO 1 2 = NC
JU24
1
2 3
2 3
K4 Contact: 2 3 = NO 1 2 = NC
JU25
1
2 3
2 3
K5 Contact: 2 3 = NO 1 2 = NC
JU26
1
2 3
2 3
K6 Contact: 2 3 = NO 1 2 = NC
JU27
1
2 3
2 3
K7 Contact: 2 3 = NO 1 2 = NC
JU28
1
2 3
2 3
K8 Contact: 2 3 = NO 1 2 = NC
NOTES:
1. For exact jumper positions as shipped see “Site Specification Data sheets” (Appendix A).
2. Bold print indicates the standard selection.
6-8
Summary of Contents for ULTRAFLOW 150
Page 2: ...DOCUMENT NO 1900 0100 01 REV E ...
Page 24: ...ULTRAFLOW 150 GAS FLOW AND TEMPERATURE MONITOR This page intentionally left blank 4 6 ...
Page 75: ...SECTION 7 0 INSTALLATION This page intentionally left blank 7 7 ...
Page 76: ......
Page 85: ...SECTION 8 0 SYSTEM CALIBRATION AND ADJUSTMENT This page intentionally left blank 8 9 ...
Page 86: ......
Page 89: ...APPENDIX A SITE SPECIFICATION DATA SHEETS ...
Page 90: ...ULTRAFLOW 150 GAS FLOW AND TEMPERATURE MONITOR This page intentionally left blank ...
Page 95: ...APPENDIX B MAINTENANCE CHECK SHEETS ...
Page 96: ... This page intentionally left blank ...
Page 101: ...APPENDIX C SPARE PARTS ...
Page 102: ... This page intentionally left blank ...
Page 105: ......
Page 106: ...APPENDIX D DRAWINGS ...
Page 107: ... This page intentionally left blank ...
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......
Page 142: ......
Page 143: ......
Page 144: ...APPENDIX E ENHANCED SERIAL PORT COMMUNICATION PROTOCOL ...