ULTRAFLOW 150 GAS FLOW AND TEMPERATURE MONITOR
C-2
TELEDYNE MONITOR LABS (TML)
ULTRAFLOW 150
“EMERGENCY” RECOMMENDED SPARE PARTS
(Parts which may be necessary to minimize instrument “Down Time” after power surges, lightning strikes, etc.)
Quantity to Stock
Part Name
TML
Part No.
System Location
1
on Site
2 – 5
on Site
5 - 10
on Site
Mean Time
Between
Replacement
*Blower Motor
980142
Purge System
1
1
2
3-5 Years
*Blower Motor
980111
Purge System
1
1
2
3-5 Years
BNC Coax Connector
(RG 180)
526512 Probe
Assembly 2
4
6 As
Needed
**Preamp PCB
Electrostatic (Standard)
1903-0200-01 TIE
Box
2
4
6
N/A
*** & ****Preamp PCB
Long Range
1903-0400-02 TIE
Box
2
4
6
N/A
***Buffer PCB
Long Range
1906-0100-02 Junction
Box
2
4
6
N/A
****Buffer PCB
Extended Long Range
1906-0100-03 Junction
Box
2
4
6
N/A
Enhanced Remote Mother
Board PCB
1803-2200-03
Enhanced
Remote Panel
1 1 2 N/A
Multi I/O PCB
1803-2500-04
Enhanced
Remote Panel
1 1 2 N/A
LCD Display
1803-1400-02
Enhanced
Remote Panel
1 1 2 N/A
Power Supply PCB (Remote)
1803-0300-02
Enhanced
Remote Panel
1 1 2 N/A
Power Supply PCB (TIE)
1860-1100-02
TIE Box
1
1
2
N/A
**TIE Mother Board
(Standard, w/Computer
Module)
1903-0100-01 TIE
Box
1
1
2
N/A
***TIE Mother Board (Long
Range, w/Computer Module)
1903-0100-02 TIE
Box
1
1
2
N/A
****TIE Mother Board
(Extended Long Range,
w/Computer Module)
1903-0100-03 TIE
Box
1
1
2
N/A
External Interface PCB
1903-1500-01 TIE
Box
1
1
2
N/A
Li-SOCl2 Battery,
Non-rechargeable,
3.6V, 1.1 Ah, 1/2AA Size
550047
TIE Box and
Enhanced
Remote Panel
1 1 2
5-10
Years
6PT I/O PC Board
UF150DI ONLY
1860-0700-01 TIE
Box
1
1
2
N/A
*The blower motor supplied with each system is dependent on effluent parameters. Consult the system
configuration parameters for your monitor for the proper blower motor.
**These parts are used on
standard monitors only
. Consult the system configuration parameters for your monitor
to determine applicability.
***These parts are used on
long range monitors only
. Consult the system configuration parameters for your
monitor to determine applicability.
****These parts are used on
extended long range monitors only
. Consult the system configuration parameters for
your monitor to determine applicability.
Summary of Contents for ULTRAFLOW 150
Page 2: ...DOCUMENT NO 1900 0100 01 REV E ...
Page 24: ...ULTRAFLOW 150 GAS FLOW AND TEMPERATURE MONITOR This page intentionally left blank 4 6 ...
Page 75: ...SECTION 7 0 INSTALLATION This page intentionally left blank 7 7 ...
Page 76: ......
Page 85: ...SECTION 8 0 SYSTEM CALIBRATION AND ADJUSTMENT This page intentionally left blank 8 9 ...
Page 86: ......
Page 89: ...APPENDIX A SITE SPECIFICATION DATA SHEETS ...
Page 90: ...ULTRAFLOW 150 GAS FLOW AND TEMPERATURE MONITOR This page intentionally left blank ...
Page 95: ...APPENDIX B MAINTENANCE CHECK SHEETS ...
Page 96: ... This page intentionally left blank ...
Page 101: ...APPENDIX C SPARE PARTS ...
Page 102: ... This page intentionally left blank ...
Page 105: ......
Page 106: ...APPENDIX D DRAWINGS ...
Page 107: ... This page intentionally left blank ...
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......
Page 141: ......
Page 142: ......
Page 143: ......
Page 144: ...APPENDIX E ENHANCED SERIAL PORT COMMUNICATION PROTOCOL ...