Commands Listed in Alphabetical Order
ACQuire:SAVEFile:SAVEWfm
This command sets or queries the path and base
fi
le name used to automatically
save one or more waveforms at the completion of a StopAfter condition (when the
StopAfter action is set to SAVEWaveform).
This is equivalent to selecting Save All Waveforms in the Stop Action section of
the Acquisition Setup dialog box and entering a
fi
le name.
Group
Acquisition
Syntax
ACQuire:SAVEFile:SAVEWfm <Qstring>
ACQuire:SAVEFile:SAVEWfm?
Related Commands
Arguments
<QSTRING>
de
fi
nes the
fi
le location path and base
fi
le name (without the
fi
le
extension). Input the
fi
le path using the form <drive>/<dir>/<base
fi
lename>. The
<drive> and one or more <dir> arguments are optional. If you do not specify
a full path name (starting with a drive letter), th einstrument stores the
fi
les at
C:\Users\<username>\TekScope\UI, where <username> is the user login name.
The <base
fi
lename> can be a Windows long
fi
le name, without an extension. Do
not use wild card characters.
The instrument automatically appends the timebase and channel number associated
with the saved waveform to the end of each base
fi
le name, before the default
.wfm extension. For example, if the base
fi
le name is Dut123, and the instrument
is using the Main timebase, then the instrument saves the channel 1 waveform to
Dut123MainC1.wfm, the channel 2 waveform to Dut123MainC2.wfm, and so on.
There is no indexing to prevent overwriting of
fi
les. Files will be overwritten
unless the base
fi
le name is changed.
Examples
ACQUIRE:SAVEFILE:SAVEWFM "DutXyz"
sets the instrument to use the base
fi
le name DutXyz to save waveform data after a StopAfter SAVEWfm condition
is met. As a full path name was not part of the command, the instrument will save
the waveform
fi
les to C:\Users\<username>\TekScope\UI.
ACQUIRE:SAVEFILE:SAVEWFM?
might return
ACQUIRE:SAVEFILE:SAVEWFM
"DUT123"
, indicating that the instrument will use the base
fi
le name DUT123 to
save waveforms in the current directory when the StopAfter action is enabled. If
DSA8300 Programmer Manual
2-57
Summary of Contents for DSA8300
Page 1: ...xx DSA8300 Digital Serial Analyzer ZZZ Programmer Manual P077057002 077 0570 02 ...
Page 2: ......
Page 8: ...Preface iv DSA8300 Programmer Manual ...
Page 9: ...Getting Started ...
Page 10: ......
Page 15: ...Syntax and Commands ...
Page 16: ......
Page 404: ...Commands Listed in Alphabetical Order 2 388 DSA8300 Programmer Manual ...
Page 405: ...Status and Events ...
Page 406: ......
Page 426: ...Status and Events 3 20 DSA8300 Programmer Manual ...
Page 427: ...Examples ...
Page 428: ......
Page 431: ...Appendices ...
Page 432: ......
Page 433: ...Appendix A Character Set DSA8300 Programmer Manual A 1 ...
Page 434: ...Appendix A Character Set A 2 DSA8300 Programmer Manual ...
Page 446: ...Appendix C Factory Default Setup Values C 8 DSA8300 Programmer Manual ...