Commands Listed in Alphabetical Order
CRMs
measures the root-mean-square voltage of the waveform within the
fi
rst
period of the measurement region.
CMEan
measures the arithmetic mean of the waveform over the
fi
rst cycle
of the measurement region.
SNRatio
measures the ratio of the amplitude of the signal to the noise within
either the eye aperture (for NRZ and RZ waveforms) or the center of the
measurement region (Pulse waveforms).
AOPTpwr
measures the True average power of an optical signal expressed
in watts.
GAIN
measures the amplitude gain between two waveforms.
OMA
measures the optical modulation amplitude, either at the eye crossing
(for NRZ waveforms) or at the speci
fi
ed center apertures of the high and
low states (Pulse waveforms).
RISe
measures the time interval between the waveform crossing the
low-reference and high-reference levels on a rising edge.
FALL
measures the time interval between the waveform crossing the
high-reference and low-reference levels on a falling edge.
PERIod
measures the time interval between two consecutive crossings on the
same slope of the waveform at the mid-reference level.
FREQuency
measures the reciprocal of the Period of the waveform.
PCROss
measures the time at which the waveform crosses the mid-reference
level on a rising edge.
NCROss
measures the time at which the waveform crosses the mid-reference
level on a falling edge.
PWIdth
measures the time interval between consecutive rising and falling
edges, measured at the mid-reference level.
NWIdth
measures the time interval between consecutive falling and rising
edges, measured at the mid-reference level.
PDUty
measures the percentage of the waveform's +Width relative to its
Period or Bit Time.
NDUty
measures the percentage of the waveform's -Width relative to its
Period or Bit Time.
BURst
measures the time between the
fi
rst and last crossings, either
positive or negative, of the waveform at the mid-reference level within the
measurement region.
RMSJitter
measures the one standard deviation (s) of the time variance
where the waveform crosses the mid-reference level.
2-264
DSA8300 Programmer Manual
Summary of Contents for DSA8300
Page 1: ...xx DSA8300 Digital Serial Analyzer ZZZ Programmer Manual P077057002 077 0570 02 ...
Page 2: ......
Page 8: ...Preface iv DSA8300 Programmer Manual ...
Page 9: ...Getting Started ...
Page 10: ......
Page 15: ...Syntax and Commands ...
Page 16: ......
Page 404: ...Commands Listed in Alphabetical Order 2 388 DSA8300 Programmer Manual ...
Page 405: ...Status and Events ...
Page 406: ......
Page 426: ...Status and Events 3 20 DSA8300 Programmer Manual ...
Page 427: ...Examples ...
Page 428: ......
Page 431: ...Appendices ...
Page 432: ......
Page 433: ...Appendix A Character Set DSA8300 Programmer Manual A 1 ...
Page 434: ...Appendix A Character Set A 2 DSA8300 Programmer Manual ...
Page 446: ...Appendix C Factory Default Setup Values C 8 DSA8300 Programmer Manual ...