Edge-type trigger sensitivity, DC
coupled, typical
Models
Trigger Source
Sensitivity
MSO5204/B, DPO5204/B
MSO5104/B, DPO5104/B
Any input channel
50 Ω path:
0.40 div from DC to 50 MHz,
increasing to 1 div at
oscilloscope bandwidth
MSO5054/B, DPO5054/B
MSO5034/B, DPO5034/B
Any input channel
50 Ω path:
1 mV/div to 4.98 mV/div –
0.75 div from DC to 50 MHz,
increasing to 1.3 div at
oscilloscope bandwidth.
≥ 5 mV/div 0.40 div from DC to
50 MHz, increasing to 1 div at
oscilloscope bandwidth.
All models
Any input channel
1 MΩ path:
1 mV/div to 4.98 mV/div –
0.75 div from DC to 50 MHz,
increasing to 1.3 div at
oscilloscope bandwidth.
≥ 5 mV/div 0.40 div from DC to
50 MHz, increasing to 1 div at
oscilloscope bandwidth.
All models
Aux in (External)
200 mV from DC to 50 MHz,
increasing to 500 mV at
250 MHz
All models
Line
Fixed
Trigger jitter
100 fs using enhanced trigger placement. 1 ps rms for low frequency, fast rise time signal, A edge,
time holdoff = 30 μs
≤100 psRMS for non edge-type trigger modes
Edge-type trigger sensitivity, not
DC coupled, typical
Trigger Coupling
Typical Sensitivity
AC Coupling
1 div for frequencies above 45 Hz.
Attenuates signals below 45 Hz.
NOISE REJ
2.5 times the DC-coupled limits
HF REJ
1.0 times the DC-coupled limit from DC to
50 kHz.
Attenuates signals above 50 kHz
LF REJ
1.5 times the DC-coupled limits for frequencies
above 50 kHz. Attenuates signals below 50 kHz
Video-type trigger formats and
field rates
Triggers from negative sync composite video, field 1 or field 2 for interlaced systems, on any field,
specific line, or any line for interlaced or non-interlaced systems. Supported systems include NTSC,
PAL, and SECAM.
Trigger specifications (cont.)
Specifications (MSO/DPO5000/B Series)
MSO70000C/DX, DPO70000C/DX, DPO7000C, MSO5000/B, DPO5000/B Series