![TANDBERG FieldView Administrator'S Manual Download Page 63](http://html2.mh-extra.com/html/tandberg/fieldview/fieldview_administrators-manual_3470527063.webp)
57
TANDBERG
FieldView Administrator Guide
D14098.02 June 2008
Cause
Solution
Destination TANDBERG FieldView Application is
set for DoNotDisturb or Offline.
Set TANDBERG FieldView Application Online.
No network path between source and destination.
Ping from the TANDBERG FieldView Device network to the
TANDBERG FieldView Application PC (Note: Ping may be blocked
by some firewalls or NAT).
Firewall is blocking connection attempt.
Review
firewall informatio
n
.
SIP is enabled but you are calling a destination
specified by local IP address
Disable SIP – see
Security
.
Call attempt from TANDBERG FieldView Application: reports Ringing and TANDBERG FieldView Device rings
for 60 seconds but then TANDBERG FieldView Application reports Call Failed.
Cause
Solution
Windows Firewall is blocking connection attempt.
Review
firewall informatio
n
.
Firewall is modifying SIP packets.
Some firewalls modify SIP packets to assist with NAT/PAT
traversal. This is not desired for FieldView operation. For Cisco
firewalls the command to disable this feature is (depends on
model/version):
no fixup protocol sip 5060
, or
no ip nat service sip udp port 5060
;
no ip nat
service sip tcp port 5060
Call attempt from TANDBERG FieldView Device fails after 60 sec with Session disconnected and no ringing
at TANDBERG FieldView Application
Cause
Solution
The PC has multiple network adapters/
connections.
If this includes a VPN connection, quit TANDBERG FieldView
Application and then disable the VPN network.
Session disconnects when video streaming enabled.
Cause
Solution
Insufficient bandwidth available.
Select a lower bandwidth configuration. See
Call Window
.
To quickly evaluate the bandwidth at the PC end, use a speed
test tool such as
www.dslreports.com/speedtest
.
Session disconnects when TANDBERG FieldView Device roams to a new access point.
Cause
Solution
New access point is on a different IP subnet so
the TANDBERG FieldView Devices IP address is no
longer valid.
Initiate a new call. It may be necessary to power cycle the
TANDBERG FieldView Device so it acquires a new IP address.
Chapter 9