1J-4 Charging System:
Generator Inspection
B944H11A06003
Generator Coil Resistance
1) Disconnect the generator coupler (1).
2) Measure the resistance between the three lead
wires.
If the resistance is out of specified value, replace the
stator with a new one. Also, check that the generator
core is insulated properly.
NOTE
When making this test, be sure that the
battery is in fully charged condition.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Resistance (
Ω
)
Generator coil resistance
0.3 – 1.2
Ω
(B – B)
∞
Ω
(B – Ground)
3) Connect the generator coupler.
No-load Performance
1) Disconnect the generator coupler (1).
2) Start the engine and keep it running at 5 000 r/min.
3) Using the multi-circuit tester, measure the voltage
between three lead wires.
If the tester reads under the specified value, replace
the generator with a new one.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Voltage (
)
Generator no-load performance (When engine is
cold)
60 V (AC) and more at 5 000 r/min
Generator Removal and Installation
B944H11A06004
Refer to “Electrical Components Location in Section 0A
(Page 0A-7)”.
Removal
1) Drain engine oil. Refer to “Engine Oil and Filter
Replacement in Section 0B (Page 0B-10)”.
1
I944H11A0002-01
B
B
B
I718H11A0005-02
1
I944H11A0003-01
B
B
B
I718H11A0006-02
Summary of Contents for SFV650
Page 1: ...SFV650 SERVICE MANUAL 9 9 5 0 0 3 6 1 9 0 0 1 E...
Page 4: ......
Page 283: ...Engine Lubrication System 1E 4 REAR CYLINDER I944H1150043 02...
Page 420: ...2D 20 Wheels and Tires...
Page 434: ...3A 12 Drive Chain Drive Train Drive Shaft...
Page 472: ...4C 10 Rear Brakes...
Page 572: ...Prepared by December 2008 Part No 99500 36190 01E Printed in Japan 572...
Page 573: ...Printed in Japan K9...