130
Function No. : 027
Function Name : Setup for descent time of presser foot
It is to set the descent time of presser foot.
[ Caution ]
This function is not available if Function No. 016. Pf Operation sets as
1)ALWAYS_DN.
The presser foot goes down at the same time as main shaft turns.
(Factory installed condition)
[ Contents ] When the main shaft turns, the presser foot goes down simultaneously.
027. PF Down Mode
1) WITH_STRT
Setting
Value
The presser foot goes down at the same time as the upper feed plate descend.
[ Contents ] When the upper feed plate descends, the presser foot goes down
simultaneously.
2) WITH_FEED
Function No. : 028
Function Name : Setup for wiper operation
It is to set the operation and kinds of wiper.
It is to prohibit the operation of wiper.
[ Contents ] Operation of wiper is prohibited. You can set this function when you
don
’
t want to use the wiper.
028. WP Operation
1) ALWAYS_OFF
Setting
Value
It is to use wiper electronically. (Factory installed condition)
[ Contents ] It is to set use of electronic wiper.
[ Caution ]
If the setup is not proper, operation of wiper can be unavailable.
2) ELEC_TYPE
Wiper is used pneumatically
[ Contents ] It is set when pneumatic wiper is used.
[ Caution ]
If the setup is not proper, operation of wiper can be unavailable.
3) AIR_TYPE