138
Function No. : 047
Function Name : Feed plate full on time
Function No. : 048
Function Name : Thread trimming full on time
Function No. : 049
Function Name : Thread Retaining Full On Time
Function No. : 050
Function Name : Wiper full on time
It is to set the operation beginning strength of the feed plate solenoid.
It is to set the time when the maximum current is permitted to solenoid.
(Factory installed condition : "200ms")
[Contents] In cases of feed plates with electric solenoids, the trimming strength at the
beginning part can be adjusted by adjusting the Full on time.
047. FF Full On Tm
0~1020ms
Setting
Value
It is to set the time strength of the thread trimming solenoid at the beginning of the operation.
It is to set the time when the maximum current is permitted to solenoid.
(Factory installed condition : "200ms")
[Contents] When thread trimming with electric solenoids, the strength of the trimming
operation at the beginning can be adjusted by adjusting the Full on time.
048. TT Full On Tm
0~1020ms
Setting
Value
It is to set the strength of the thread retaining solenoid operation at the beginning.
It is to set the time when the maximum current is permitted to solenoid.
(Factory installed condition : "200ms")
[Contents] In cases of thread retaining with electric solenoids, the operation strength at
the beginning can be adjusted by adjusting the full on time.
[Caution] The function is not used on SPS/A-Series Electronic Control Sewing Machines.
049. TR Full On Tm
0~1020ms
Setting
Value
It is to set the beginning strength of the wiper solenoid.
It is to set the time when the maximum current is permitted to solenoid.
(Factory installed condition : "200ms")
[Contents] In cases of wipers with electric solenoids, the strength of the wiper operation
at the beginning can be adjusted by adjusting the Full on time.
050. WP Full On Tm
0~1020ms
Setting
Value