76
Caution) The sewing limit function is always defaulted at DISABLE and the sewing limit is set at the
standard size for each type at the factory.
3-18) Quick Origin Search Motion Function for 1811 Machines
< Before >
< After >
As SPS-1811 machines is equipped with reverse devices, origin search motion is performed as shown in the
Before picture and feeds back to the starting point of sewing. However, if there is no reverse device,
search motion takes place very slowly. This quick origin search motion function ensures fast origin search
as shown in the After picture and feeding back to the starting point of sewing.
Starting point of sewing
Origin
Origin
Starting point of sewing
130mm
< Before >
< After >
60mm
X-axis expanded limit
130mm
140mm
5mm
5mm
< < M a i n M e n u > >
1 . P a r a m e t e r S e t
2 . P r o g r a m
3 . B o b b i n W i n d
A. Press MODE to select Parameter Set in Main
Menu.
Refer to the following for set-up.
< P a r a m e t e r S e t >
0 8 3 . F F O r i g n 1 8 1 1
0 8 4 .
A F C D o w n T i m e
0 8 5 . A F C U p T i m e
B. Use the direction change cursor in Parameter
Set and select 083. FFOrign 1811.