159
Function No. : 099
Function Name: Upper thread holding time setting (C-Series AIR BAG model)
Set the needle thread holding time by the upper thread holder after trimming.
The upper thread holder’s holding time is set. (Default: 1[sec])
[Contents] The function prevents the remaining thread on the needle from being sown to the
sewing materials or being entangled after trimming, affecting the sewing quality
negatively. In general, when 1ms is set, the thread is released after one stitching.
099. ThreadHoldTm
0~5
Setting
Value
Function No. : 100
Function Name: Clamp sensor setting
The left, right sensors detect the proper attachment of the clamp. If more than one sensor fails to detect
the clamp, the machine does not start operating. This function is applied to the removable clamp [for Air
bag model].
The clamp sensor is not used.
[Contents] Without sensor
’
s clamp detection, forced sewing can be conducted.
The clamp sensor is used.
[Contents] When either one of the left and right sensors fails to detect the clamp, sewing cannot
be performed.
100. Clamp Sensor
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 101
Function Name: Airbag mode setting
If the clamp is removable (Cassette type), set the airbag mode.
The airbag mode is not used.
[Contents] Regular clamp, not removable clamp (Cassette Type), is used.
The airbag mode is used.
[Contents] Removable clamp (Cassette type) is used.
101. Cassette Type
1) DISABLE
2) ENABLE
Setting
Value