Function No. : 105
Function Name: Setting of the emergency stop function during jump
It disables or enables the emergency stop function during the jump section.
Disabled (default when released from factory)
[Description]
Enabled
[Description]
105. Jump EM Stop
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 106
Function Name: Setting of the needle cooling function (applicable to SPS/C-Series only)
The needle gets heated due to the rubbing of the sewing material and the needle. To cool off the needle,
this function sprays chill air. This function determines the usage mode.
It is always working during sewing except for the jump motion.
[Description] It reduces the needle temperature by spraying chill air throughout the sewing process
except for jump motion.
Its motion starts or ends depending on the set operating cycle.
[Description] In accordance with the timer cycle set in "13 NeedleOffTime" and the cool-off duration
set in "12 NeedleControl," the cold air is released to reduce the needle temperature. However, the
time is based on the actual sewing time which excludes the jump motion time.
106. NeedleCoolSet
1) NORMAL
2) TIMER
Setting
Value
Function No. : 107
Function Name: Setting of the needle cooling function time
(applicable to SPS/C-Series only)
It sets the time to release cold air to cool off the needle.
It sets the time to release cold air (default value: 4[ms])
[Description] Cold air is released during the set time. To enable this function, "2)TIMER" should be
selected in "111 NeedleCoolSet."
107. NeedleControl
00~100(0.5sec)
Setting
Value
Disabled
[Description]
3) DISABLE