Commissioning
Verti-Mix 951-1651, Verti-Mix 951-L, 1251-L, Verti-Mix 1501 D-3101 D 05.16
91
4.
Start the machine and switch the
conveyor on.
5.
Set the control dial (2) to position 2
(minimum drive speed).
6.
Turn the screw at the trimmer
potentiometer P2 to change the minimum
drive speed of the conveyor until it runs at
the desired speed (current approx.
0.6-1.9 A).
7.
Set the control dial (2) to position 10
(maximum drive speed).
8.
Turn the screw at the trimmer
potentiometer P3 to change the maximum
drive speed of the conveyor until it runs at
the desired speed (max. current 2.5 A).
9.
Finally, turn the control dial and observe
the conveyor to check the entire control
range.
Adjust the control range as described in
steps 5-8 if necessary.
With the control dial range
being reduced, the other
hydraulic functions are
reduced as well as long as the
conveyor is running.
In case of a conveyor failure,
the other hydraulic functions
can still be operated.
10.
Close the casing of the control set.
Fig. 53
5.13
Mount control set on the tractor
5.13.1
Mount holder with pocket for Bowden cable control set
1. Fix the holder (1) with the pocket (2) for the
Bowden cable control set within view and
easy reach at an appropriate spot in the
tractor’s cabin.
2. Insert the Bowden cable control set into the
pocket (2).
Fig. 54