Commissioning
Verti-Mix 951-1651, Verti-Mix 951-L, 1251-L, Verti-Mix 1501 D-3101 D 05.16
93
Charge battery
If the voltage of the additional battery falls below 10.5 V, charging
via the battery management is no longer possible!
In this case, a separate power supply unit with connecting cable is
required.
The battery is charged if the three-pole plug of the E-control set is connected with the tractor.
Precondition for the charging procedure is a socket in the tractor which is not switched via the ignition
system. Otherwise, the battery is only charged with the ignition system switched on.
Approx. 11 hours are required to completely charge an empty battery. In order to ensure trouble-free
operation, provide for a sufficient minimum charging time.
Operation of weighing device without connection to tractor
Minimum charging time of
battery
15 min
0.5 h
30 min
1.0 h
45 min
1.5 h
60 min
2.0 h
If the required minimum charging time cannot be reached, an additional power supply unit will be
required which enables charging of the battery independently of the tractor. The electronic system of
the charging equipment prevents overloading. The power supply unit is connected with the three-pole
plug of the E-control set by means of a charging cable.
5.15
Set deflector plate
WARNING
Risk of injury due to movements of the machine or its working
tools!
Secure the machine against accidental starting, rolling and actuation!
Mechanical deflector plate
1.
Lower the dosage gate(s) completely.
2.
Unscrew the nut (4).
3.
Move the adjusting sheet (3)
●
up (1): the deflector plate (5) swivels
out to its maximum extent when the
dosage gate is lifted.
●
down (2): the deflector plate (5)
swivels out to its minimum extent
when the dosage gate is lifted.
4.
Retighten the nut (4).
Fig. 57