Remedy of malfunctions
164
Verti-Mix 951-1651, Verti-Mix 951-L, 1251-L, Verti-Mix 1501 D-3101 D 05.16
(1)
Entry plate
(2)
Connection, pressure line P
(3)
Directional control valve for e. g. hydraulic
cylinder of dosage gate, crossover
conveyor drive, hydraulic cylinder of
discharge conveyor, hydraulic cylinder of
counter-cutters etc.
(4)
End plate
(5)
Connection, return line T (R;S)
(6)
Control block for variable conveyor speed
(optional extra)
Fig. 122
10.3
Weighing device
It is absolutely imperative to observe the included operating
instructions for the weighing device.
Malfunction
Cause
Remedy
Device cannot be switched on
No power supply
Check connecting cable.
Switch on power supply, check power
supply battery.
Wrong polarity
Check polarity connecting cable.
(The devices are equipped with an
automatic fuse).
Device displays bars (top or
bottom)
Device
Pull the terminal box plug out of the
weighing computer and watch display.
If the bars disappear, the weighing
computer functions properly.
Terminal box
Pull out the plugs of all weighing rods, the
terminal box being plugged into the
weighing computer. Watch display. If the
bars disappear, the display functions
properly.