Remedy of malfunctions
Aperion 2101, Aperion 2401, Aperion 3401 04.18
169
9.3
Emergency manual operation in case of failure of electrical system
WARNING
Risk due to dangerous movements of movable components
when actuating the emergency manual operation function!
Before actuating the emergency manual operation function, make
sure that third persons leave the
machine’s hazardous area.
In case of failure of the electrical system, the
solenoids for switching the directional
control/seat valves can be actuated directly at the
electro-hydraulic control block via the emergency
manual operation function.
•
Pre-selection valves:
Use a blunt object to push in the armature
of the solenoid at the respective control
valve to actuate the required hydraulic
functions.
•
Intermediate plate and end plates:
Screw in the knurled screw at the required
directional control/seat valve.
Fig. 125
Unscrew the knurled screws completely again after having carried
out the emergency manual operation function!
Summary of Contents for Aperion 2101
Page 2: ......
Page 42: ...Product description 42 Aperion 2101 Aperion 2401 Aperion 3401 04 18 Fig 36...
Page 44: ...Product description 44 Aperion 2101 Aperion 2401 Aperion 3401 04 18 Tyre pressures with 26 5...
Page 176: ...Circuit diagrams 176 Aperion 2101 Aperion 2401 Aperion 3401 04 18 Chassis of Aperion Fig 131...
Page 182: ...Circuit diagrams 182 Aperion 2101 Aperion 2401 Aperion 3401 04 18 Chassis of Aperion Fig 135...
Page 186: ...Circuit diagrams 186 Aperion 2101 Aperion 2401 Aperion 3401 04 18 Circuit diagram Fig 137...
Page 190: ...Circuit diagrams 190 Aperion 2101 Aperion 2401 Aperion 3401 04 18 Circuit diagram Fig 139...
Page 196: ...Index 196 Aperion 2101 Aperion 2401 Aperion 3401 04 18...