![Strautmann Aperion 2101 Translation Of The Original Operating Instructions Download Page 147](http://html1.mh-extra.com/html/strautmann/aperion-2101/aperion-2101_translation-of-the-original-operating-instructions_1383802147.webp)
Service and maintenance of machine
Aperion 2101, Aperion 2401, Aperion 3401 04.18
147
6.
Check the oil level in the oil storage tanks
(1):
Remove oil reservoir.
Remove drain plug and drain oil.
Clean all parts.
Close drain plug again.
Check oil and change in case of
contamination.
Quantity when filled: Hydraulic oil
HLP 46 approx. 100ml per oiler
Top up oil
Level: Approximately half filled.
Reinstall oil reservoir at the chassis
cylinder.
7.
Properly readjust the travelling height.
Fig. 102
Each of the four oil storage tanks must be half filled with hydraulic oil
HLP 46. The quantity when filled is 100 ml each.