97
Appendix B.
Setting Dispenser Type
(The Factory Default Setting for Dispenser Type is “COIN”).
To make a change to the Dispenser Type feature, follow the step by step procedure outlined below.
Note: The five-position switch and red selection button are located on the dispenser control board.
For machines with multiple dispensers, these settings must be set on each dispenser control board for
the feature to be activated.
IMPORTANT: Please note the original switch settings before starting this procedure. You will need
to return the switches to this original setting to assure proper operation after making any changes. As
a convenience, you can enter these original settings in the diagram to the right by simply marking an
“X” for UP (ON) or DOWN (OFF) on each switch.
1.
Activate the Dispenser Type programming mode by setting:
Switch 1–ON; Switch 2-OFF; Switch 3-OFF; Switch 4-ON; Switch 5-ON
2.
Press the red selection button one time.
3.
Advance to the Dispenser Type selection step by setting;
Switch 1-ON; Switch 2-OFF; Switch 3-OFF; Switch 4 –OFF; Switch 5-OFF
4.
Press the red selection button ten times.
5.
Now set switches to desired setting Choice numbers 1 through 5 as per the chart below. Once
you’ve made your selection, press the red selection button one time.
Example: Set switches to match Choice 2 if you want the Dispenser Type set to “TOKEN”.
6.
End the programming sequence by resetting the switch to their original settings, and then press
the red selection button one time to put the machine back into service.
PARAMETER TABLE –
DISPENSER TYPE
CHOICE
SETTING
SWITCH POSITIONS
SW2
SW3
SW4
SW5
1
COIN
OFF
OFF
OFF
ON
2
TOKEN
OFF
OFF
ON
OFF
3
BILL
OFF
OFF
ON
ON
4
CARD
OFF
ON
OFF
OFF
5
TICKET
OFF
ON
OFF
ON
Appendix C.
Custom Dispenser Value
(The Factory Default Setting for Dispenser Value is “ $00.00”).
To make a change to the Dispenser Value, follow the step by step procedure outlined below.
1 2 3 4 5