81
limit settings for the affected device. Check the Program settings.
15-30
TRACKING CODES
– These codes are intended for use by SCM troubleshooting personnel. If code
persists, contact the nearest SCM service center.
31
DISPENSER
OUTPUT
BLOCKED
–
The dispenser (coin, bill, ticket) sensor is blocked. Check the
dispenser counting sensor and associated connections.
32
DISPENSER IS
EMPTY –
The dispenser (coin, bill, ticket) is empty. If dispenser is not empty, check the
sold out sensor connections.
33
DISPENSER IS
JAMMED –
The dispenser (coin, bill, ticket) is jammed. Check the dispense path.
34
DISPENSER HAS
OVERPAID –
The dispenser (coin, bill, ticket) has issued an extra item. Check
for debris
mixed in with the coins or bills. Debris can be counted as an extra “item”. If the error is from a ticket dispenser, check
the tickets for tears in the area around the ticket notch. Extra notches (tears) can be counted as a ticket.
35
BILL DISPENSER
COMMUNICATION
ERROR – The bill dispenser is not talking. Check the
communication (data) cable connections. Make sure the dispenser has power to it as well.
36
Not Used – Contact factory if error persists after resetting.
37
Not Used – Contact factory if error persists after resetting.
38
Not Used – Contact factory if error persists after resetting.
39
BILL DISPENSER CARTRIDGE IN
WRONG POSITION
– One of the bill cartridges in a multi-
note dispenser is in the wrong position. Check position of all bill cartridges.
7.6.1.2
Resetting Dispenser Error Conditions
You can either reset a dispenser error condition by pressing the red reset button on the dispenser
board or you can press the Machine reset button on the main control module.
Reset Button
Each dispenser is equipped with a
push button
that can be used to reset the dispenser from an
error condition. It is only necessary to reset the
coin dispenser that is displaying the error flash
code. Allow at least 45 seconds after releasing
the button, for the entire reset process to be
completed. The flash code should change back to
the steady flashing pattern if the error was
successfully reset.
Coin Dispenser w/o Door
RESET BUTTON