82
7.7
Coin Acceptor Troubleshooting (not BE or DLR models)
The coin acceptor used in the Guardian XP is the IDX-X10 coin acceptor. This coin acceptor includes
a troubleshooting LED indicator to aid in programming and troubleshooting this device. The status
for each LED color and condition is shown below.
·
Steady Green – Normal.
·
Steady Red - Program switch is in a position other than 0 (normal run position)
·
Flashing Yellow - Coin acceptor is being disabled by the controller. Machine is OOS.
·
No Light – No power to the device or a defective board. Check cable for connection and
continuity.
See the section of this manual titled “Setting Up Tokens” for more information regarding the coin
acceptor and for information that explains how to “train” the acceptor to identify quarters, dollar
coins and tokens. You can also visit the IDX web site at
www.idxinc.com
for more information on
programming or troubleshooting this device.
7.8
Printer Troubleshooting (not DLR model)
The optional Hengstler X-56 printer includes a Red and Green LED to indicate the status of the
printer. The LED conditions will indicate normal operation as well as the “out of paper” and “printer
failure” conditions.
For a paper, or cutter error, press the black plunger in to remove any debris. Pull the black plunger
out to reload the paper. See the section titled “Loading Paper in the Printer” in the Quick Start Guide
in the beginning of this manual for more information.
If both LED’s are off, check the printer cable at both ends for a proper connection. Note: The printer
cable plugs into the connector marked with a blue colored identifier at the main control board.
If the printer is not in an error mode, but will not print receipts or reports, check the printer setting
menu for proper programming.
LED Indicator
(X-10 shown with the
cover removed).