11
board is used to identify the value of coin the hopper is to dispense. The table below shows the
setting for each coin value. Also, note that the token setting is also included in the table.
If you have changed the hopper value, you will need to reprogram your Button Settings from the
main menu of the Guardian XP Control Module. This is necessary so that the Guardian XP will
return the correct change for any refund due.
DISPENSER VALUE SETTINGS
Value
SW1
SW2
SW3
SW4
SW5
Token
DOWN
DOWN
DOWN
DOWN
DOWN
$.05
DOWN
DOWN
DOWN
DOWN
UP
$.10
DOWN
DOWN
DOWN
UP
DOWN
$.20
DOWN
DOWN
DOWN
UP
UP
$.25
DOWN
DOWN
UP
DOWN
DOWN
$.50
DOWN
DOWN
UP
DOWN
UP
$1.00
DOWN
DOWN
UP
UP
DOWN
$2.00
DOWN
DOWN
UP
UP
UP
$5.00
DOWN
UP
DOWN
DOWN
DOWN
$10.00
DOWN
UP
DOWN
DOWN
UP
$20.00
DOWN
UP
DOWN
UP
DOWN
$50.00
DOWN
UP
DOWN
UP
UP
If you wish to use a value not in this table please see Appendix C to set the value. When done please
set all the switches in the dispenser down to use this custom value. Usually this is done for tokens.
Reset Button
5 Position
Dip Switch
1 2 3 4 5
Default Settings
(quarters)