[SERVICE POSITION TO CHECK THE CAMERA SECTION]
Connection to Check the Camera Section
If you have remove the Cabinet (L), set the camera to the “Forced camera power ON” mode to check the camera section.
Operate the camera functions of the zoom and focus using the adjustment remote commander (with the HOLD switch set in
the OFF position).
Setting the “Forced Camera Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01 and
press the PAUSE button of the adjustment remote
commander.
Exiting the “Forced Camera Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page : 0, address: 01, and set data: 00.
AC IN
AC power
adaptor
Adjustment remote
commander (RM-95)
Control switch block
(FK-1850)
VM-027 board
EVF block assembly
Lens assembly
Cabinet (R)
Cabinet (L)
CD-349 board
FJ-035 board
VC-270 board
DC-IN connector
(88P)
(51P)
(72P)
(16P)
Harness (PT-128)
(88P)
Mechanism deck