5-37
DCR-PC115/PC115E/PC120BT/PC120E
2. Backlight Adjustment (VM-027 board)
Set the backlight luminance.
If deviated, the image may become dark or bright.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
3
of CN008 of VC-270 board
(EVF LED DA)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
90, 91
Specified Value
A = 2.10 ± 0.05Vdc
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
91
Change the data and set the voltage
(A) of Pin
3
of CN008 to the
specified value.
3
D
91
Press PAUSE button.
4
D
91
Read the data, and this data is
named D
91
.
5
Convert D
91
to decimal notation,
and obtain D
91
’. (Note)
6
Calculate D
90
’ using following
equation. (Decimal calculation)
D
90
’ =D
91
’– 96
7
Convert D
90
’ to a hexadecimal
number, and obtain D
90
. (Note)
8
D
90
D
90
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note:
Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
3. Bright Adjustment (VM-027 board)
Set the D range of the RGB decoder used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin
4
of CN008 of VC-270 board
(EVF VG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
95
Specified Value
A = 7.20 ± 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
95
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to the
specified value.
3
D
95
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 5-1-19.
Pedestal
Pedestal
A
2H