5-33
DCR-PC115/PC115E/PC120BT/PC120E
17. Strobe White Balance Adjustment & Check
Adjust and check the white balance when the strobe light flashes.
Subject
Paper which reflection rate is 18%
(1.0m from the front of the lens)(Note 1)
Adjustment Page
F
Adjustment Address
2E, 2F
Specified Value
FA to FF or 00 to 06
Note 1:
Background paper (J-2501-130-A). Perform this adjustment in the
dark room or use a dark box.
Note 2:
Any light other than the strobe light should not light up the plate.
Note 3:
This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment”, “Auto White Balance
& LV Standard Data Input”, “Auto White Balance Adjustment”
and “Strobe Light Level Adjustment”.
Note 4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note 5:
After the power is turned on, this adjustment can be done only
once.
Note 6:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
B-Y data
R-Y data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
FLASH ......................................................................... OPEN
(Press FLASH ( ) button and set to the forced flash mode
( ), and press PHOTO button.)
3)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
F4
Write down the data.
3
D
F4
04
Set the data, and press PAUSE button.
4
6
01
B9
Set the data, and press PAUSE button.
5
Check the flashing.
6
6
02
Check that the data is “01”.
(Note7)
7
6
02
00
Set the data.
8
6
01
E7
Set the data, and press PAUSE button.
9
Check the flashing.
10
6
02
Check that the data is “01”.
11
6
04
29
Set the data.
12
1
Check that the R-Y data and B-
Y data (Note 6) satisfy the
specified value.
Note7:
The adjustment data will be automatically input to page: F, address:
2E, 2F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
02
00
Set the data.
3
6
04
00
Set the data.
4
D
F4
Set the data which is written
down at step 2 of “Adjusting
method”.
5
D
F4
Press PAUSE button.
6
0
01
00
Set the data.
RadarW
RadarW
RadarW
RadarW
RadarW