5-31
DCR-PC115/PC115E/PC120BT/PC120E
14. Mechanical Shutter Adjustment
Adjustment Page
F
Adjustment Address
5C to 75
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 5C to 75.
Note:
Press the PAUSE button of the adjustment remote commander each
time to set the data.
15. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03LA
Type B: ENC03LB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
1B00 to 2500
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
STEADY SHOT (Menu display) ...................................... ON
2)
ZOOM ......................................................................... Center
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(VM-027 board SE3450)
1
6
04
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note2)
Yaw sensor check
(VM-027 board SE3451)
3
6
04
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note2)
Note2:
Don’t move the camcorder.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
04
00
Set the data.
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
3)
Select page: 0, address: 01, and set data: 00.
Address
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
b6C
6D
6E
6F
70
71
72
73
74
75
Data
70
9E
A6
A5
A8
20
A7
0C
6E
09
B5
07
5B
06
7A
05
8F
2E
6F
4B
91
46
7B
39
83
33