7
3.1.
Setting of end switches IRC (incremental)
First check the value of parameter “r”, if is equal to used motor.
If the control panel has already been used in the past, we recommend performing a
complete reset of the control panel by calling the function , see the description
in point 3.2
After switching on the control panel power supply, which has already been set in the
past, an attempt will always be made to find the reference position. The display shows
. that no reference has been made (reference = end point search where the
IRC sensor is reset, by default the reference point is set to the closed position)
Subsequently, a message appears on the display or which indicates
that the door is looking for a reference point (r_CL = referencing to position closed,
r_OP referencing to position open, see parameter settings
The reference position is searched at reduced speed, see parameter settings
When searching for a reference at the moment of reaching the stop (end position),
the drive is overloaded and after the time set by the parameter has elapsed, it
evaluates as reaching the reference point and resets the position sensor.
Unintentional evaluation of the end position can occur if the motor is overloaded when
searching for a reference when there is no free movement of the door - check the
door mechanism.
If the control panel was set up correctly in the past and the door mechanism has not
changed, the drive is ready for use after searching for a reference point (reference).
During referencing, this process can be interrupted and new settings can be made,
proceed according to point 3.1.1
3.1.1.
Setting of movement direction:
1.
2.
press 9s
press 3s
press
5s
direction saved
Setting is possible only from STOP state, “stop” must be shown on display.
1)
press and hold knob button – during approx. 9 s. it passes to setting of movement,
and display shows „ dir ̄ˍ “
(by holding the knob button, after 4 seconds there is at first displayed „Par“ „Par“ it is
!
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...