30
32
34
36
38
PULL SWITCH - NO contact (always opens and if the safety devices
allow that the gate closes after the end of set time)
+24 V
„EMERGENCY OPEN - NO contact - after activation during alarm
gate opens into position set by Par „9“, and after the end of set
time Par „A“ it closes in alarm closing mode
+
+24 V
FAS (EPS) „fire contact“ – type of input according to setting
Parameter type of input EPS
+
+24 V
RESET – NO contact
+
+24 V
LOCK - NO contact on the panel – in case of detector alarm, it
resets
+
+24 V
The remaining inputs are connected to the power terminal block X1.
b)
output side (lower part of the terminal block X2)
26
warning light 0V
27
warning light +24V
Maximum load of output warning light 24VDC/1A
28
alarm NO
29
alarm NC
30
alarm COM
31
relay COM (terminals X2:32 to X2:38)
without 230V – output acording setting
33
discharged battery - output according setting
safety end switches - output according setting
35
safety brake/ loack of the gate – output according setting
middle possition LS1 - output according setting
37
opened – output according setting
closed - output according setting
Maximum load of output relays X2:32 - X2:38 -max.60V DC/AC, 1A each, 5A total for all
contact strip 8k2 - 0V (to connect contact strip we use closed loop 8,2 kΩ
between X2:39 and X2:40)
contact strip 8k2 - +24V (to connect contact strip we use closed loop 8,2 kΩ
between X2:39 and X2:40)
smoke/heat detectors 0V (to connect detectors we use closed loop 4,7 kΩ
between X2:41 and X2:42)
smoke/heat det24V (to connect detectors we use closed loop 4,7 kΩ
between X2:41 and X2:42)
Function of „Smoke“ alarm – when detector is activated, gate opens into the
set position and after the end of set time it closes.
detectors used for function „Smoke“ alarm 0V (to connect detectors we use
closed loop 4,7 kΩ between X2:43 and X2:44)
detectors used for function „Smoke“ alarm +24V (to connect detectors we
use closed loop 4,7 kΩ between X2:43 and X2:44)
8
+
9
10
11
12
39
40
41
42
43
44
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...