17
Parameter – time of battery discharging
Time after which the gate, held on batteries, closes during power
failure. Range of values:
•
0-30 minutes
•
„-„ = depends on battery condition and
load Default = 10
Parameter – Emergency Open width
Setting of width for automatic open in alarm and activation of button
Emergency Open (input X2:+, X2:9) Range of values:
•
30–100 % gate width
•
„-„ = according to the setting of middle position
Note: When we have end switches NES it is possible to set only „-“ and the position
follows the setting of middle position.
Default = 50%
Parameter – Emergency Open time
Setting of time during which the gate waits in the set position
after activation of button Emergency Open.
Range of values: 5–999
seconds Default = 10
Parameter – Permanent Open
Selection of input function of pull switch (input X2:+, X2:8)
•
0 – without permanent open – standard pull switch
•
1 – function “permanent open” is activated – if the input of pull switch
is connected then it opens always when it is possible – closes only in alarm
•
2 – function permanent
close Default = 0
Parameter – Return after alarm
What happens after cancelling the alarm:
•
0 = after cancelling the alarm, do nothing
•
1 = return to the state before alarm
•
2 = after alarm Open
•
3 = after alarm Close
•
4 = after alarm Reset will finish closing as the alarm will be
active Default = 0
Parameter – Passing of closed position
Is used to pass the end position “closed” during alarm – can close the
door beyond the end position when closing the alarm - special
application.
Range of values: 0–100 % from 6 % gate height. Default = 0
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...