28
7.2.
Errors report on functional display
F
lashes as a basic error because the drive reference has not been performed.
It is necessary to switch the drive off and on again and call up the drive
referencing, see 3.1
Error IRC failure of communication.
It did not reach the position in time, went to “stop”, can be reset by new
impulse to movement. If this alarm is repeted it is nececary to recalibrate time
see 3.1.5. In specific cases with special motors where is longer acceleration
under the load can be detected this fold then set parameter “U” and both “y”
on maximum values and then recalibrate the time. After recalibration can be
parameters “U” and both “y” reduced to previous values.
Error of movement direction, went to „stop”, can be reset by new impulse
to movement from the keyboard of the control box, external inputs are blocked.
Before correction of the error, the keyboard of the control box must be locked
and unlocked, otherwise it does not react. (3.1.1.–3.1.5.)
Error of EEPROM – internal memory for saving parameters, end switches
and counter. If the data do not correspond, they can be reset by restart.
Error of control amount possition IRC. Indicated when deleted end possitions
or by internal error. In case of this fold reset end possitions (3.1.1.–3.1.5.).
Error of limit switches activation of safety switch, error of position. Reset
positions (3.1.).
Error of time calibration. Set the calibration time (3.1.5.).
Overload error - The drive has been overloaded. The error is reset by a new
impulse to move. If repeated, the time and torque must be recalibrated, see
section 3.1.5. Time and torque calibration.
Torque Error - Stopped by drive overload. The error is reset by a new impulse
to move. If it is repeated, the engine power setting must be adjusted or the
time and torque must be recalibrated, see section 3.1.5. Time and torque
calibration
Activation of input safety break (input X1:13,X1:14). Used for connection of
door lock sensor - see 1.4
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...