31
9.3.
Power terminal block (terminal block X4)
L, N, PE power supply 1 x 230 V TN-S
1, 2, 3
drive motor phases
S
shealding of motor cable - connected with ground
PE
ground of motor cable
4
shealding of cable IRC sensor
5, 8
power supply of IRC sensor
6, 7
output signal from IRC sensor
10.
Control panel
10.1.
Key switch
Keys switch on control panel in position 0 = buttons “Open” and “Close” not active,
eventually not active also external inputs see setting DIP 5 point 5.2
In case of activation of fire detectors - switch on and switch off = reset of alarm
10.2.
Descriptions of control panel
OPEN
= button open gate
STOP
= button stop, by continuous pressing for 10 seconds is
activated reset of fire detectors
CLOSE
= button to close gate
On control panel of FSTronic there is installed keyboard with buttons OPEN, STOP, CLOSE. On the
keyboard there are also LED diodes, which display all current states of the control. This enables
the gate operator to determine particular states and potential gate alarms.