16
5.3.2.
Parameters and their values
Parameter - Audio & visual signalization
- warning light (output X2:26, X2:27)
during movement
during alarm
•
0 =
active with delay
active with delay, during alarm duration
•
1 =
not active
active with delay, during alarm duration
•
2 =
active without delay
active without delay, only during movement
•
3 =
not active
active without delay, only during movement
•
4 =
not active
active with delay, only during movement
Parameter – Time of pre-flash - alarm
Range of values: 0–999 seconds,
Note: In case of setting time delay follow rules in standard EN 14637.
Default = 0
Parameter – Time of pre-flash under normal operation
Range of values: 0–999 seconds,
Note: (when setting parameter „1“ “warning light” on value 1, there is running only
the time of pre-flash, warning light is not active)
Default = 0
Parameter – number of attempts to close
Range of values:
•
0-10 attempts
•
„-„ = endless number of attempts
Note: (according to the setting DIP6 gate moves back or fully
opens) Default = 0
Parameter – delay of closing attempts
Range of values: 1–50
seconds Default = 10
Parameter – time of automatic closing
Time after which the gate, opened by pull switch, starts to
close. Range of values: 3–999 seconds
Default = 10
Parameter – duration of movement back
Motion back after collision with obstacle.
Range of values: 1–10 seconds
Default = 3
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...