9
3.1.3.
Setting of middle position:
press
press 5s
middle position
saved
1)
We can start setting of middle position after saving the position “opened” or by
pressing button knob, there is displayed:
a)
„End - “ – if the middle line lights up, the position has been already set
b)
„End - “ – if the middle line flashes, position has not been set yet
2)
Afterwards press keyboard buttons OPEN or CLOSE (keyboard has to be unlocked
by key switch) and move gate into position, in which we want to set the middle position.
•
If the actual position of gate corresponds with the required position it is possible to
save the setting – by pressing STOP button on keyboard and holding the button
for 5 seconds.
•
After saving the middle position (by holding STOP on keyboard for 5 seconds),
we automatically proceed to setting of lower end position.
•
It is possible to skip setting of the middle position by pressing the knob button –
and proceed to setting of the lower end position – IT IS NECESSARY TO SET the
middle end position to put the gate into standard operation, the middle position is
used for additional functions (e.g. emergency open…)
3.1.4.
Setting of lower end position „closed “:
press
press 5s
lower position
saved
1)
We can start setting of the lower end position after saving the middle position
or by pressing the knob button, on display is shown:
a)
„End ˍ “ – if the lower line lights, the position has been already set
b)
„End ˍ “ – if the lower line flashes, the position has not been set yet
2)
Afterwards press keyboard buttons OPEN or CLOSE (keyboard has to be unlocked
by key switch) and move gate into position, in which we want to set the lower end
position.
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...