10
•
If the actual position of gate corresponds with the required position it is possible
to save the setting – by pressing STOP button on keyboard and holding the button
for 5 seconds.
•
After saving the lower end position (by holding STOP on keyboard for 5 seconds),
we automatically proceed to calibration of opening time.
•
It is possible to skip setting of the lower end position by pressing knob button –
and proceed to setting of the calibration of opening time.
It is possible to use function „End -“ setting of end positions, for manual movement of gate
in emergency situations – only used for service (for example, when passing the range of
end positions or during the activation of safety end switches).
To put the gate into operation, it is necessary to do final calibration of operation time.
This is a safety function, which is important when preparing gate for standard operation.
3.1.5.
Calibration of time and torque (max. motor force)
Calibration of time and torque is a necessary task for the complete commissioning of the
door. If this function is not performed correctly, an error will be displayed, ie a
movement time error or a maximum torque error . This function is safety and is used
to check the movement time and the maximum torque during operation.
During calibration, the maximum running time between the end positions is measured also
the maximum torque when moving the door - this maximum torque can be exceeded during
standard door movement by the value set by the parameter , thus increasing insensitivity
in the event of an obstacle. The time for which the maximum torque can be exceeded is set
in parameters and
press
press
Setting of calibration:
It is important to set lower (“closed”) and upper (“opened”) end position.
1)
Display shows „CL“ – by pressing keyboard button CLOSE – to get to position “closed”
(position “closed” has to be set). After setting the position “closed” the motor stops
and display shows „t OP“
2)
By pressing keyboard button OPEN and its holding (without interrupting) we get into
position “opened” (position “opened” has to be set). In “opened” position the motor
stops and unit goes to normal operation – setting of direction and positions
is successfully completed)
If the pressing/holding of keyboard button is interrupted before reaching the opened
position, the setting automatically returns to point 1) and it is necessary to repeat the
calibration process. You have to return to position “closed” and repeat the calibration
process.
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...