4
After connection of external control devices (controls and end switches) the drive requires
only a control of function. It is important to ensure that the end switches function well.
Their incorrect setting or electric connection can cause damage of mechanical part of gate.
Before putting into operation the installation of mechanical part of gate has to be
completely finished to avoid mechanical damage of gate when starting the motor.
Before starting connect only:
1.
Motor cable FSTronic IRC-FI (can be part of motor)
-
Motor power - terminal block X4 terminals 1, 2, 3, S, PE (picture 1.1)
o
terminal 1 (motor phase) – wire marking XM/U (eventually 1)
o
terminal 2 (fáze motoru) – wire marking XM/V (eventually 2)
o
terminal 3 (fáze motoru) – wire marking XM/W (eventually 3)
note. - by switching the motor phases, it changes the direction of rotation
- see point 3.1.1 setting the direction of movement
o
terminal S (shielding of motor cable) – grey wire without marking
o
terminal MPE (ground) – wire green-yellow
-
Communication cable of possition sensor IRC – end switches – terminal
block X4 nterminals 4, 5, 6, 7, 8 (picture 1.2)
o
terminal 4 (shielding of sensor cable) – grey wire without marking
o
terminals 5 a 8 (power supply for sensor 24V)
terminal 5 (0V) – sensor wire marking X1/3 (eventually 5)
terminal 8 (+24V) – sensor wire marking X1/4 (eventually 8)
note - the polarity of the sensor power supply must be correct!!
o
terminals 6 a 7 (output signal from sensor)
terminal 6 – sensor wire marking X1/1 (eventually 6)
terminal 7 – sensor wire marking X1/2 (eventually 7)
note - the output signals of the sensor can be reversed, this changes the
direction and the direction of movement must be set / confirmed again,
see.point 3.1
1.2
1.1
Summary of Contents for FSTronic IRC-FI
Page 36: ...www somati system cz 36 12 2 FSTronic IRC FI CONTROL BOARD DPS ...
Page 38: ...www somati system cz 38 12 4 FSTronic IRC FI CONNECTION OF FIRE DETECTORS ...
Page 39: ...www somati system cz 39 12 5 FSTronic IRC FI Connection aof additional battery module ...
Page 42: ...www somati system cz 42 GridScan PRO SY 2000 FSS GridScan PRO SY 2000 LO ...
Page 43: ...www somati system cz 43 GridScan MINI FSS GridScan MINI PNP NPN ...