Section 06
ELECTRICAL
Subsection 07
(TESTING PROCEDURE)
06-07-9
DUCATI CDI SYSTEM TESTING
Série S
IGNITION SYSTEM TESTING
SEQUENCE
In case of ignition problems, check the following
in the prescribed order until the problem can be
solved.
1. Sparking/spark plug condition;
2. Electrical connectors;
3. Ignition switches, tether cord cap and emer-
gency switch;
4. Ignition coil output;
5. Trigger coil output;
6. High voltage coil output.
LIGHTING SYSTEM TESTING
SEQUENCE
1. Electrical connectors;
2. Magneto output (lighting generator coil).
Testing Conditions
Voltage measurements are always taken upon
starting the vehicle. Readings taken when the en-
gine is running will be higher than indicated range.
Part temperature must be approximately 20°C
(room temperature), otherwise readings could be
distorted.
Analysis of Readings
Voltage Readings
When testing the different magneto components,
it is important to take into consideration that read-
ings vary according to the force applied onto the
manual starter. It is therefore important to employ
enough force upon each trial.
The reading must be 3 times within or above the
range indicated in the corresponding table. If the
reading is too low, the part is considered to be de-
fective and it must be replaced.
Resistance Readings
Place multimeter selector switch to
Ω
in order to
measure resistance. Readings must be within the
indicated range. Otherwise, the part is considered
to be defective and must be replaced.
Intermittent Ignition Problems
It is difficult to make a diagnostic in the case of
intermittent ignition problems. Thus, problems
occurring only when the engine operating temper-
ature is normal must be checked in similar condi-
tions.
In most cases when problems are caused by tem-
perature or vibrations, these can only be solved by
replacing parts. Most problems cannot be detect-
ed when the engine is stopped.
Multiple Problems
As a matter of fact, more that one component can
be defective. As a result, if the problem remains
although a part was replaced, start over the whole
verification from the beginning in order to identify
the other defective component.
1. SPARKING
During this operation, it is important to use the
snowmobile spark plug and not a new one. Bring
the plug in contact with the engine. If no spark is
produced, replace the spark plug with a new one
and do the test again.
2. ELECTRICAL CONNECTOR
TESTING
Make sure that none of the connectors are dis-
connected.
-
CAUTION
When taking measurements, it is useless to
try to start the vehicle since readings would
then be distorted.
Summary of Contents for Formula S 1998
Page 1: ......
Page 2: ...1998 Shop Manual VOLUME 1 TUNDRA II LT TOURING E LE FORMULA S S ELECTRIC SL SKANDIC 380 500...
Page 314: ...TUNDRA II LT ANNEX 1...
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ...SKANDIC 380 500 ANNEX 2...
Page 319: ......
Page 320: ......
Page 321: ......
Page 322: ......
Page 323: ...FORMULA S ANNEX 3...
Page 324: ......
Page 325: ......
Page 326: ......
Page 327: ......
Page 328: ...FORMULA SL ANNEX 4...
Page 329: ......
Page 330: ......
Page 331: ......
Page 332: ......
Page 333: ...TOURING E LE FORMULA S ELECTRIC ANNEX 5...
Page 334: ......
Page 335: ......
Page 336: ......
Page 337: ......
Page 338: ......