Section 06
ELECTRICAL
Subsection 02
(WIRING DIAGRAMS)
06-02-5
TYPICAL
1. Receptacle
2. Housing
ACCESSORIES INSTALLATION
On all
electric start models
: The direct current
(DC) utilizes the snowmobile frame as ground
“wire” while all alternating current (AC) consum-
ers (lights, heated grips, fuel gauge, etc.) utilize a
separate ground wire.
Never interconnect AC and DC grounds as an AC
voltage drop will result. When installing accesso-
ries on
any
snowmobile, connect their wires di-
rectly to the YELLOW and YELLOW/BLACK
lighting coil wires.
Even if
manual start models
have an AC ground
to the chassis (on voltage regulator), all accesso-
ries utilize a ground wire isolated from chassis.
When an electric starter kit is installed, the volt-
age regulator and its ground wire are replaced by
a voltage rectifier/regulator unit permitting a com-
pletely isolated AC circuit.
;
WARNING
Never secure electrical wires/cables with
fuel lines. Keep wires away from any rotat-
ing, moving, heating, vibrating or sharp
edge. Use proper fastening devices as re-
quired.
A00E1FA
1
2
Summary of Contents for Formula S 1998
Page 1: ......
Page 2: ...1998 Shop Manual VOLUME 1 TUNDRA II LT TOURING E LE FORMULA S S ELECTRIC SL SKANDIC 380 500...
Page 314: ...TUNDRA II LT ANNEX 1...
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ...SKANDIC 380 500 ANNEX 2...
Page 319: ......
Page 320: ......
Page 321: ......
Page 322: ......
Page 323: ...FORMULA S ANNEX 3...
Page 324: ......
Page 325: ......
Page 326: ......
Page 327: ......
Page 328: ...FORMULA SL ANNEX 4...
Page 329: ......
Page 330: ......
Page 331: ......
Page 332: ......
Page 333: ...TOURING E LE FORMULA S ELECTRIC ANNEX 5...
Page 334: ......
Page 335: ......
Page 336: ......
Page 337: ......
Page 338: ......