Technical data
11.5 Operating conditions
SITRANS P500 with HART
204
Operating Instructions, 12/2014, A5E02344528-09
11.5
Operating conditions
Rated conditions
Differential pressure and flow rate
Installation conditions
•
Mounting position
Any
Ambient conditions
•
Ambient temperature
Note
Observe the temperature class in hazardous areas.
Pressure transmitter
-40 … +85 °C (-40 … +185 °F)
Display not legible: -40 … -20 °C (-40 … -4 °F)
Display legible: -20 … +85 °C (-4 … +185 °F)
Storage temperature
-50 … +90 °C (-58 … +194 °F)
•
Climate class
Condensation
Relative humidity 0 ... 100 %
(Condensation permitted)
•
Degree of protection
IP66/IP68 and NEMA 4x (with appropriate cable gland)
•
Electromagnetic compati-
bility
Interference emission and
interference immunity
To IEC 61326 and NAMUR NE 21
Permitted pressures
As per 97/23/EC Pressure Equipment Directive
Medium conditions
•
Process temperature
Measuring cell with sili-
cone oil filling
-40 … +125 °C (-40 … +257 °F)
(Note that there is no medium flow through the pressure caps during
normal operation at a temperature > 100 °C.)
Vibration resistance
•
Reference conditions
Specifications apply to devices
•
With and without steel mounting bracket
•
Pressure caps PN160
•
Aluminum dual-chamber housing
•
Wall mounting with 4 screws
Vibrations (sine)
IEC 60770-1
10 ... 58 Hz, 0.3 mm (0.01 inch)
58 ... 500 Hz, 20 m/s² (65.62 ft/s²)
1 octave/min; 5 cycles/axis
Continuous shocks (half-
sine)
IEC 60770-1
250 m/s² (820 ft/s²), 6 ms,
2000 shocks/axis