Level input
6.25 ... 1250 mbar
0.625 ... 125 kPa
2.51 … 502 inH
2
O
0.032 ... 6250 mbar
3.2 ... 625 kPa
12.54 … 2509 inH
2
O
Maximum expansion (Turn-Down)
•
25 kPa/250 mbar/100 inH
2
O
125 kPa/1250 mbar/502 inH2O
625 kPa/6250 mbar/2509 inH
2
O
3200 kPa/32 bar/465 psi
200:1
Low measuring limit
•
Measuring cell with silicone oil
filling
-100 % of maximum measuring span or
50 kPa a/500 mbar a/7.25 psi a
Optionally available: Flange variant for
vacuum applications up to 3 kPa a/30 mbar a/0.44 psi a
High measuring limit
100% of maximum span
Start of scale value
Between the measuring limits (continuously adjustable)