Operate
6.2 Parameter description
SITRANS P500 with HART
120
Operating Instructions, 12/2014, A5E02344528-09
Purpose:
Display/ change the O-ring material
Description:
This parameter records the material of the O-rings that are used. The O-
rings can be exchanged. If the O-ring material has been changed, enter the
material currently used in this parameter.
"2.6.2 Remote Seal"
"2.6.2.1 Number"
Factory setting:
e.g. 0, or as shown on the order
Setting range:
•
Min. 0
•
Max. 2
Purpose:
Display/ change the number of remote seals used
Description:
This parameter stores the number of remote seals used.
"2.6.2.2 Remote Seal Type"
Factory setting:
e.g. DN100-PN16, or as shown on the order
Adjustment range:
16 characters
Purpose:
Display / change the remote seal type
Description:
This parameter stores the remote seal type.
"2.6.2.3 Isolator material"
Factory setting:
e.g. stainless steel 14404, or as shown on the order
Adjustment range:
16 characters
Purpose:
Display / change the remote seal membrane material
Description:
This parameter stores the remote seal membrane material.
"2.6.2.4 Fill Fluid"
Factory setting:
e.g. silicone oil M50, or as shown on the order
Adjustment range:
16 characters
Purpose:
Display / change the remote seal filling medium
Description:
This parameter stores the remote seal filling liquid.
"2.6.2.5 Extension Length"
Factory setting:
e.g. 30 mm, or as shown on the order
Adjustment range:
16 characters