160
Step 4: Telephony Service Cutover
b.
View the
Diagnostic Log
to verify that no errors are being
reported; see "Viewing the Diagnostic Log" on page 162.
c.
View the
Call Monitor
to verify that calls are passing through the
ETM Appliance; see "Monitoring Calls in Real Time" on page
164.
To verify that a 1012 or 1024 Appliance is operating normally
1.
View the front of the Appliance and verify the following LEDs:
I/F
—Illuminated green, indicating communication between the
Controller Card and Digital Trunk Interfaces.
PMC
—Illuminated green, indicating communication between the
Controller Card and the DSP Mezzanine Card.
Status
—Illuminated green, indicating that there are no errors.
Error
—Not illuminated, indicating that there are no errors.
If the
Status
LED is not green and blinking, execute a
SHOW
STATUS
command from the
Console
port to determine the cause.
2.
Follow a comprehensive phone number test list developed by your
organization and make calls to verify that lines are working correctly.
Verifying ETM
®
1012/1024
Appliance
Operation